Capacitor testing
The correct functioning of a capacitor can be measured with (for example) a FLUKE multimeter. The value specified by the manufacturer is 0.22 μF (microfarad). Over time, a capacitor’s performance can be expected to decline. The left photo shows a broken capacitor: the measured value is 0.131 nF (nanofarad) = 0.000131 μF The right photo shows a properly functioning capacitor: the measured value is 0.249 μF. This is 13% higher than the specified value, but this does not affect proper operation. The value specified by the manufacturer is a chosen ideal value for the expected average engine rpm. This value is therefore